Safety, Health and Injury Management and Wellbeing

Respiratory protection

Our role is to develop and assist in the implementation of the UWA safety, health and wellbeing programs in order to minimise the risk of injury, illness and property damage.

We provide consultancy and other services to promote best practice and legislative compliance in all University and related activities.

The University shall take all practicable measures to ensure that no employee is exposed to an atmosphere that is or may be injurious to health.

The University shall also ensure that no person at the workplace is exposed to an atmospheric contaminant at concentrations in excess of exposure standards or an unbreathable atmosphere as outlined in Division 3 of the Occupational Safety and Health Regulations 1996.

In complying with this requirement, the University shall, as far as practicable, avoid the presence of the contaminant concerned or control the level of the contaminant using:

  • a ventilation or exhaust system that effectively extracts the contaminant or, if impractical
  • other suitable means.

Where it is not possible to so remove the contaminant the University shall provide suitable respiratory protective equipment in accordance with Section 6 of AS/NZS 1715.

Guidance is available in AS/NZS 1715 Selection, use and maintenance of respiratory protective devices and AS/NZS 1716 Respiratory protective devices.

  1. Classification of hazards
  2. Types of protective devices
  3. Selection
  4. Fitting
  5. Instruction
  6. Maintenance

Classification of hazards

  • Deficiency of oxygen
  • Particulate contaminants
  • Gaseous or vapour contaminants.

Back to top

Types of protective devices

There are two main types:

  • air purifying devices
  • devices which supply air.

Air purifying devices

These devices can not be used in oxygen depleted atmospheres.

Air purifying devices fall into four major categories.

  • Dust masks – used for protection against nuisance dusts such as sawdust, chalk, plant-related and sanding dusts. These are generally not suitable for toxic substances
  • Gas filters - filter fitted into a half face mask, full face mask or hood, suitable for removing low concentrates of certain gases and vapours. Filters have limited use and storage lives and are specific to certain gases or vapours. They are not generic - a specific filter needs to be matched to a specific make of mask.
  • Particulate filters - used to remove finely divided solid or liquid particles from inhaled air. Particulate filters have a prefix 'P' and a number indicating a class corresponding to filtration efficiency against a laboratory challenge aerosol of sodium chloride. P1, P2 and P3 filters roughly correspond to the former L, M and H cartridges. There are three types of particulate filter suitable for filtering finely divided solid or liquid particles, or both, from inhaled air. These are classified, in accordance with tests in AS 1716, as:
    • CLASS (P1) Intended for use against mechanically generated particulates, (for example, silica, asbestos).
    • CLASS (P2) Intended for use against both mechanically and thermally generated particulates, (for example, metal fumes).
    • CLASS (P3) Intended for use against all particulates including highly toxic materials, (for example, beryllium). Class P3 requires a full face mask.

      Note: Cotton fibre or plastic foam pads are not permitted.

  • Combined gas and particulate filters - filter combinations are used where both hazard types may exist.

Devices which supply air

These include airline respirators and self-contained breathing apparatus. Use of this equipment requires detailed training. Example of use areas may be spray booths, PC4 biohazard labs and sandblasting. Further details are available from UWA Safety and Health.

Back to top

Selection

Factors which influence selection include:

  • adequacy of warning available
  • type of hazard
  • concentration of contaminant
  • acuteness of hazard, that is, the effect of short exposure.
  • time spent in contaminated atmosphere
  • nature of the working environment
  • activity of the wearer
  • mobility of the wearer
  • whether for routine or emergency use.

If in doubt contact UWA Safety and Health.

Back to top

Fitting

Achieving a good facial seal is essential. Facial hair such as beards and sideburns prevent a close fit and spectacles or even facial irregularity may also present problems. Tests involving detection of odour and gross leakage should be carried out as described in AS/NZS 1715.

Back to top

Instruction

Training in the correct use of equipment is required by law.

Instruction shall include:

  • how to recognise the need to wear the device
  • importance of conscientiously wearing the device
  • how the device works
  • application and limitations of the device
  • how to determine if it is working properly
  • the time for which the device will give protection
  • procedure for dealing with an emergency when the device is being worn
  • importance of not removing the device until it is safe to do so
  • importance of taking care of the device, such as cleaning, maintenance, storage.

Back to top

Maintenance

The head of school/section/unit shall ensure that all respiratory protective devices are regularly checked, properly stored and maintained, cleaned and replaced (both mask and cartridges as appropriate) according to applicable standards and manufacturer's advice. Users should be supervised to ensure that any instructions specific to this equipment are followed.

Back to top